Entry  Fri Sep 25 11:08:33 2015, Steve, Update, SUS, wire standoffs wireStandOff_SOS.PDF
    Reply  Mon Dec 14 14:08:49 2015, Steve, Update, SUS, Ruby wire standoffs update 
       Reply  Tue Apr 12 09:14:57 2016, Steve, Update, SUS, Ruby wire - v - groove cut pictures Sapphire_prism_wire_standoff.JPG
       Reply  Wed Jun 1 15:01:56 2016, Steve, Update, SUS, wire standoffs update 06011603.PDF06011602.PDFsapphire_stand_off_v2.pdfside_OSEM_ETMY.jpg5p2wsf.png
          Reply  Thu Jun 2 16:35:44 2016, Koji, Update, SUS, wire standoffs update sapphire_stand_off_v3.pdfarrangement-v3.pdf
             Reply  Thu Jun 1 16:21:55 2017, Steve, Update, SUS, wire standoffs update 
                Reply  Mon Jun 5 10:30:45 2017, Steve, Update, SUS, ruby wire standoff pictures A087_R.png.bmpA097_chipped_edges.png.bmpA099_cal_wire.png.bmpA101_cal_wire_43_micron.png.bmpAl_SOS_R39mm.jpg
                   Reply  Mon Jul 17 16:22:01 2017, Steve, Update, SUS, ruby wire standoff pictures contacting_ridge.bmpcontacting_ridge.png
          Reply  Tue Aug 30 15:44:28 2016, Steve, Update, SUS, wire standoffs update 
             Reply  Tue Oct 11 10:38:51 2016, Steve, Update, SUS, wire standoffs update A028_-_20161010_170319.jpgA027_-_20161010_170202.jpg
             Reply  Fri Jan 27 14:50:04 2017, Steve, Update, SUS, wire standoffs update 
                Reply  Fri Jan 27 15:36:17 2017, Koji, Update, SUS, wire standoffs update 
                   Reply  Thu Feb 23 09:32:20 2017, Koji, Update, SUS, wire standoffs update Sapphire_prism_1(A015).pngSapphire_prism_2(A016).pngSapphire_prism_3(A014).png
                Reply  Thu Feb 2 12:17:48 2017, Steve, Update, General, USB microscope 
                   Reply  Thu Feb 9 08:03:08 2017, Steve, Update, General, USB microscope ordered 
                      Reply  Thu Feb 23 14:50:26 2017, Steve, Update, General, USB microscope returned 
Message ID: 12071     Entry time: Tue Apr 12 09:14:57 2016     In reply to: 11878
Author: Steve 
Type: Update 
Category: SUS 
Subject: Ruby wire - v - groove cut pictures 

The ruby wire standoff V groove cuts are looking good.

I will request free sample of  sapphire prizm where one side would have SOS's R cylindrical surface.

The present plan to have the v-groove on this prism.

 

Attachment 1: Sapphire_prism_wire_standoff.JPG  1.617 MB  Uploaded Tue Apr 12 10:48:29 2016  | Hide | Hide all
Sapphire_prism_wire_standoff.JPG