Author: Steve 
Type: Update 
Category: PEM 
Subject: ETMX floor vs table noise 

 

Quote:

Objective:  measure the noise floor on the optical table and the floor so we can decide if the table needs better anchoring before swapping in

                   the larger optical table

The accelerometrs labeled as MC1 ( just north east  of IOO chamber floor ) and MC2 ( north east leg of MC2 table floor ) were moved:

MC1 to the floor at the north west leg of optical table.

MC2 is in the north east corner of the optical table

Atm2 was taken after table leg bolts were tighed at 40 ft/lb

The spectrum looks similar to ETMY       except  the Z direction 

ETMY .

Conclusion: up to 20 Hz this set up is good.

Attachment 1: ETMX_X_floor_vs_table.png  55 kB  | Hide | Hide all
ETMX_X_floor_vs_table.png
Attachment 2: ETMX_Y_floor_vs_table.png  53 kB  | Hide | Hide all
ETMX_Y_floor_vs_table.png
Attachment 3: ETMX_Z_floor_vs_table.png  53 kB  | Hide | Hide all
ETMX_Z_floor_vs_table.png
Attachment 4: MC1@ETMX.jpg  175 kB  | Hide | Hide all
MC1@ETMX.jpg
Attachment 5: MC2@1Winno.jpg  188 kB  | Hide | Hide all
MC2@1Winno.jpg
Attachment 6: MC2@ETMXtable.jpg  204 kB  | Hide | Hide all
MC2@ETMXtable.jpg
ELOG V3.1.3-