Entry  Tue Dec 8 15:57:16 2015, yutaro, Summary, LSC, Power recycling gain estimation from arm loss measurement 
    Reply  Fri Dec 11 09:35:44 2015, yutaro, Update, LSC, Power recycling gain estimation from arm loss measurement LaserOptikAR.png
       Reply  Fri Dec 11 13:28:36 2015, Koji, Update, LSC, Power recycling gain estimation from arm loss measurement 
          Reply  Fri Dec 11 15:37:50 2015, yutaro, Update, LSC, Power recycling gain estimation from arm loss measurement PRG_plot.png
Message ID: 11874     Entry time: Fri Dec 11 15:37:50 2015     In reply to: 11873
Author: yutaro 
Type: Update 
Category: LSC 
Subject: Power recycling gain estimation from arm loss measurement 

Attached is the plot of relation between the average arm round trip loss and power recycling gain. 2 % loss due to PR3 AR reflection is taken into account.