Entry  Mon Nov 30 12:19:38 2015, yutaro, Update, Computer Scripts / Programs, image capture 
    Reply  Sat Dec 5 12:02:25 2015, yutaro, HowTo, Cameras, When image capture does not work... 
       Reply  Sat Dec 5 21:28:33 2015, Koji, HowTo, Cameras, When image capture does not work... 
          Reply  Sat Dec 5 21:57:32 2015, yutaro, HowTo, Cameras, When image capture does not work... 
Message ID: 11824     Entry time: Mon Nov 30 12:19:38 2015     Reply to this: 11851
Author: yutaro 
Type: Update 
Category: Computer Scripts / Programs 
Subject: image capture 

On VIDEO.adl, Image Capture and Video Capture did not seem to work and gave me some errors, so I fixed following two things:

1. just put one side of a USB cable to Pianosa the other side of which was connected to Sensoray; I don't know why but this was unconnected.

2. slightly fixed /users/sensoray/sdk_2253_1.2.2_linux/imsub/display-image.py as fpllows   

L52:       pix[j, i] = R, G, B     ->     pix[j, i] = int(R), int(G), int(B)  

It seems to work, at least for some cameras including ETMYF and ITMYF. 