40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Nov 21 00:45:30 2015, Koji, Update, IOO, IMC fix PDRFsignal_cable.JPGQsignal_cable1.JPGQsignal_cable2.JPGQsignal_cable3.JPG
    Reply  Sat Nov 21 00:46:33 2015, Koji, Update, IOO, IMC OLTF IMC_OLTF.pdfPMC_noise_comparison.pdf
       Reply  Sun Nov 22 12:12:17 2015, Koji, Update, IOO, IMC OLTF 
    Reply  Sun Nov 22 07:09:01 2015, rana, Update, IOO, IMC fix 
       Reply  Sun Nov 22 12:07:09 2015, Koji, Update, IOO, IMC fix 
          Reply  Mon Nov 23 22:12:10 2015, Koji, Update, IOO, LO level check for the IMC demod board IMG_2137.JPGIMG_2138.JPG
             Reply  Wed Nov 25 04:24:21 2015, rana, Update, IOO, LO level check for the IMC demod board 
                Reply  Wed Nov 25 10:07:10 2015, Koji, Update, IOO, LO level check for the IMC demod board 
                   Reply  Wed Nov 25 16:46:10 2015, Koji, Update, IOO, LO level check for the IMC demod board D990511-40m_151123.pdf
                      Reply  Wed Nov 25 20:07:35 2015, rana, Update, IOO, LO level check for the IMC demod board 
                   Reply  Mon Nov 30 14:12:14 2015, ericq, Update, LSC, LO level check for the LSC RF distribution box 
                      Reply  Mon Nov 30 15:17:57 2015, Koji, Update, LSC, LO level check for the LSC RF distribution box 
Message ID: 11811     Entry time: Wed Nov 25 16:46:10 2015     In reply to: 11808     Reply to this: 11812
Author: Koji 
Type: Update 
Category: IOO 
Subject: LO level check for the IMC demod board 

Awwww. I found that the demod board has the power splitter (PSCJ-2-1) with one output unterminated.
This power splitter should be removed.

https://dcc.ligo.org/D1500443

Attachment 1: D990511-40m_151123.pdf  133 kB  Uploaded Wed Nov 25 18:55:10 2015  | Hide | Hide all
D990511-40m_151123.pdf