Message ID: 11798     Entry time: Sun Nov 22 12:12:17 2015     In reply to: 11795
Author: Koji 
Type: Update 
Category: IOO 
Subject: IMC OLTF 

Well. I thought a bit more and now I think it is likely that this is just the servo bump as you can see in the closed-loop TF.

Quote:

6. Broad feature from 40kHz to 200kHz. The IMC loop is adding the noise. This is the frequency range of the PC drive. Is something in the PC drive noisy???