Message ID: 11791     Entry time: Thu Nov 19 17:06:57 2015
Author: Koji 
Type: Configuration 
Category: CDS 
Subject: Disabled auto-launching RT processes upon FE booting 

We want to startup the RT processes one by one on boot of FE machines.

Therefore /diskless/root/etc/rc.local on FB was modified as follows. The last sudo line was commented out.

for sys in $(/etc/rt.sh); do
    #sudo -u controls sh -c ". /opt/rtapps/rtapps-user-env.sh && /opt/rtcds/cal\
tech/c1/scripts/start${sys}"

    # NOTE: we need epics stuff AND iniChk.pl in PATH
    # we use -i here so that the .bashrc is sourced, which should also
    # source rtapps and rtcds user env (for epics and scripts paths)

    # commented out Nov 19, 2015, KA
    # see ELOG 11791 http://nodus.ligo.caltech.edu:8080/40m/11791
    # sudo -u controls -i /opt/rtcds/caltech/c1/scripts/start${sys}
done