Entry  Wed Nov 11 22:11:15 2015, Koji, Update, SUS, PSL/IOO maintenance, TM SUS check up TM_SUS.pdfTM_SUS_SD.pdf
    Reply  Thu Nov 12 09:15:56 2015, Steve, Update, SUS, ITMX osems ITMX.png
       Reply  Fri Nov 13 15:20:24 2015, Steve, Update, SUS, OSEMs OSEMs.pngPOSbiasOFF.png
    Reply  Thu Nov 12 09:41:02 2015, Steve, Update, PSL, PMC PMC_ITMX.png
    Reply  Tue Nov 17 00:57:21 2015, ericq, Update, SUS, ITMX UL calmed? TM_nov17.pdfITMX_sensortrend.png
       Reply  Tue Nov 17 15:59:23 2015, rana, Update, SUS, ITMX UL calmed? 
Message ID: 11774     Entry time: Tue Nov 17 15:59:23 2015     In reply to: 11770
Author: rana 
Type: Update 
Category: SUS 
Subject: ITMX UL calmed? 

Although this noise is bad, we have always had these kind of humps around the bounce mode. Our interpretation in the past was that this was due to poor alignment of the OSEM in the frame, leading to a large vertical to horizontal coupling. Once you implement the BLRMS for the SUS channels, we'll be able to trend the noise over long periods of time.