Entry  Tue Nov 17 14:31:25 2015, ericq, Update, CDS, 16Hz frame writing temporarily disabled 
    Reply  Tue Nov 17 20:57:43 2015, ericq, Update, CDS, 16Hz frame writing running again 
Message ID: 11772     Entry time: Tue Nov 17 14:31:25 2015     Reply to this: 11777
Author: ericq 
Type: Update 
Category: CDS 
Subject: 16Hz frame writing temporarily disabled 

To test the effect on EPICS latency, I've restarted daqd with modified ini files which disable all frame writing of 16Hz channels. 

This happened at GPS:1131835955 aka Nov 17 2015 22:52:18 UTC

Last night, I started running a script written by Dave Barker that monitors a specified EPICS channel (in this case C1:IOO-MC_TRANS_SUM), to look for seconds in which it does not update the expected number of times. This is still running, so I will be able to compare the rate of EPICS slowdowns before and after this change. 

I will revert back to the nominal state of things in a few hours, or until someone asks me to. 