[Yutaro, Koji]
Recently "EPICS Freeze" is so frequent and the normal work on the MEDM screen became almost impossible.
As a part of the investigation, all 19 realtime processes were stopped in order to see any effect on the probem.
IN FACT, when the realtime processes were absent (still slow machines were running), frequency of EPICS Freeze
became much less. This might mean that the issue is related to the data collection of the slow channels. We need more investigation.
After the testing, all the processes were restored although it was not so straghtforward. Particularly, c1sus DAC had an error which was
not visible from the CDS Status screen. We noticed it as suspension damping was not effective on any of the vertex suspensions.
This has been solved by restarting c1x02 process. |