40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
Wed Nov 11 22:11:15 2015, Koji, Update, SUS, PSL/IOO maintenance, TM SUS check up 
|
Thu Nov 12 09:15:56 2015, Steve, Update, SUS, ITMX osems
|
Fri Nov 13 15:20:24 2015, Steve, Update, SUS, OSEMs 
|
Thu Nov 12 09:41:02 2015, Steve, Update, PSL, PMC
|
Tue Nov 17 00:57:21 2015, ericq, Update, SUS, ITMX UL calmed? 
|
Tue Nov 17 15:59:23 2015, rana, Update, SUS, ITMX UL calmed?
|
|
Message ID: 11760
Entry time: Fri Nov 13 15:20:24 2015
In reply to: 11755
|
Author: |
Steve |
Type: |
Update |
Category: |
SUS |
Subject: |
OSEMs |
|
|
Are they oscillating or not ?
Quote: |
The ITMX OSEMS are oscillating.
|
ETMX, ETMY and MC2 POS _biases are off. Why ?
The Epics MEDMs screens are going blank in ~3-5 minutes reluctantly. |
|
|
|