Message ID: 11748
Entry time: Tue Nov 10 11:41:56 2015
In reply to: 11745
|
Author: |
Koji |
Type: |
Update |
Category: |
LSC |
Subject: |
Updated interpretation of peaks |
|
|
FYI: I've also reported the similar mod depths of
11M: 0.194
55M: 0.234
in ELOG11036 with a different kind of measurement method. |