Thu Nov 5 02:18:32 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker
|
Fri Nov 6 15:56:00 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker    
|
Mon Nov 9 11:34:51 2015, yutaro, Update, LSC, FSR and linewidth measurements with phase tracker 
|
Mon Nov 9 14:24:36 2015, yutaro, Update, LSC, FSR and linewidth measurements with phase tracker
|
Mon Nov 9 15:59:06 2015, ericq, Update, LSC, FSR and linewidth measurements with phase tracker
|
Mon Nov 9 16:58:59 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker  
|
Tue Nov 10 02:34:28 2015, gautam, Update, LSC, Updated interpretation of peaks 
|
Tue Nov 10 11:06:02 2015, yutaro, Update, LSC, Updated interpretation of peaks 
|
Tue Nov 10 11:40:03 2015, Koji, Update, LSC, Updated interpretation of peaks
|
Tue Nov 10 16:34:00 2015, yutaro, Update, LSC, Updated interpretation of peaks
|
Fri Nov 13 17:33:39 2015, gautam, Update, LSC, g-factor measurements
|
Tue Nov 10 11:41:56 2015, Koji, Update, LSC, Updated interpretation of peaks
|
Fri Nov 13 15:48:16 2015, gautam, Update, LSC, Phase tracker calibration using Rubidium standard 6x
|
|
Message ID: 11742
Entry time: Mon Nov 9 15:59:06 2015
In reply to: 11741
Reply to this: 11743
|
Author: |
ericq |
Type: |
Update |
Category: |
LSC |
Subject: |
FSR and linewidth measurements with phase tracker |
|
|
Quote: |
- modulation depth = 0.390 +/- 0.062
|
There are two modulation frequencies that make it to the arm cavities, at ~11MHz and ~55MHz. Each of these will have their own modulation depth indepedent of each other. Bundling them together into one number doesn't tell us what's really going on. |