40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Nov 5 02:18:32 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker 
    Reply  Fri Nov 6 15:56:00 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker Xcalib.pdfYcalib.pdfY_scan_log.pdf2015-11-05_phase_tracker_calib.dat.zip2015-11-04_y_arm_scan.dat.zip
       Reply  Mon Nov 9 11:34:51 2015, yutaro, Update, LSC, FSR and linewidth measurements with phase tracker plt.pngfitresult_and_code.zip
          Reply  Mon Nov 9 14:24:36 2015, yutaro, Update, LSC, FSR and linewidth measurements with phase tracker 
             Reply  Mon Nov 9 15:59:06 2015, ericq, Update, LSC, FSR and linewidth measurements with phase tracker 
                Reply  Mon Nov 9 16:58:59 2015, gautam, Update, LSC, FSR and linewidth measurements with phase tracker Y_scan.pdfmodDepth.pdfMatlab_code.zip
                   Reply  Tue Nov 10 02:34:28 2015, gautam, Update, LSC, Updated interpretation of peaks Y_scan.pdfmodDepth.pdf
                      Reply  Tue Nov 10 11:06:02 2015, yutaro, Update, LSC, Updated interpretation of peaks HOMlocation.pnghomfit.png
                         Reply  Tue Nov 10 11:40:03 2015, Koji, Update, LSC, Updated interpretation of peaks 
                            Reply  Tue Nov 10 16:34:00 2015, yutaro, Update, LSC, Updated interpretation of peaks homfit2.png
                               Reply  Fri Nov 13 17:33:39 2015, gautam, Update, LSC, g-factor measurements findGFactor.zip
                      Reply  Tue Nov 10 11:41:56 2015, Koji, Update, LSC, Updated interpretation of peaks 
       Reply  Fri Nov 13 15:48:16 2015, gautam, Update, LSC, Phase tracker calibration using Rubidium standard 6x
Message ID: 11741     Entry time: Mon Nov 9 14:24:36 2015     In reply to: 11740     Reply to this: 11742
Author: yutaro 
Type: Update 
Category: LSC 
Subject: FSR and linewidth measurements with phase tracker 

I'd like to add a few calculation results, mode matching ratio for Y arm and modulation depth.

Here I assumed peaks marked in the bottom figure shown in elog 11738 as resonances of carrier and modulated sidebands and others as resonances of HOM. 

 

- mode matching ratio = 94.92 +/- 0.19 % WRONG

How I calculated: for each peak of carrier, you can find 6 peaks of HOM resonaces. Then I calculated the sum of the hight of 6 peaks divided by the hight of carrier resonance peak, and took average of this values for 3 resonance peaks of carrier.

 

- modulation depth = 0.390 +/- 0.062 WRONG

How I calculated: I took average of the hight of 6 peaks of modulated sideband resonance, and normalized it with the hight of peaks of carrier resonance. Using the relation 'normalized hight' = (J_1(m)/J_0(m))^2, I got modulation depth, m. 

 

 