Summary
I've not really been able to make additional progress with the new 'fb1' DAQ. It's still flaky as hell. Therefore we're still using old 'fb'.
Issues
mx_stream
The mx_stream processes on the front ends initially run fine, connecting to the daqd and transferring data, with both DAQ-..._STATUS and FE-..._FB_NET_STATUS indicators green. Then after about two minutes all the mx_stream processes on all the front ends die. Monit eventually restarts them all, at which point they come up green for a while until the crash again ~2 minutes later. This is essentially the same situation as reported previously.
In the daqd logs when the mx_streams die:
Aborted 2 send requests due to remote peer 00:30:48:be:11:5d (c1iscex:0) disconnected
Aborted 2 send requests due to remote peer 00:14:4f:40:64:25 (c1ioo:0) disconnected
Aborted 2 send requests due to remote peer 00:30:48:d6:11:17 (c1iscey:0) disconnected
Aborted 2 send requests due to remote peer 00:25:90:0d:75:bb (c1sus:0) disconnected
Aborted 1 send requests due to remote peer 00:30:48:bf:69:4f (c1lsc:0) disconnected
mx_wait failed in rcvr eid=000, reqn=176; wait did not complete; status code is Remote endpoint is closed
disconnected from the sender on endpoint 000
mx_wait failed in rcvr eid=000, reqn=177; wait did not complete; status code is Connectivity is broken between the source and the destination
disconnected from the sender on endpoint 000
mx_wait failed in rcvr eid=000, reqn=178; wait did not complete; status code is Connectivity is broken between the source and the destination
disconnected from the sender on endpoint 000
mx_wait failed in rcvr eid=000, reqn=179; wait did not complete; status code is Connectivity is broken between the source and the destination
disconnected from the sender on endpoint 000
mx_wait failed in rcvr eid=000, reqn=180; wait did not complete; status code is Connectivity is broken between the source and the destination
disconnected from the sender on endpoint 000
[Thu Oct 1 19:00:09 2015] GPS MISS dcu 39 (PEM); dcu_gps=1127786407 gps=1127786425
[Thu Oct 1 19:00:09 2015] GPS MISS dcu 39 (PEM); dcu_gps=1127786408 gps=1127786426
[Thu Oct 1 19:00:09 2015] GPS MISS dcu 39 (PEM); dcu_gps=1127786408 gps=1127786426
In the mx_stream logs:
controls@c1iscey ~ 0$ /opt/rtcds/caltech/c1/target/fb/mx_stream -r 0 -W 0 -w 0 -s 'c1x05 c1scy c1tst' -d fb1:0
mmapped address is 0x7f0df23a6000
mmapped address is 0x7f0dee3a6000
mmapped address is 0x7f0dea3a6000
send len = 263596
Connection Made
isendxxx failed with status Remote Endpoint Unreachable
disconnected from the sender
daqd
While the mx_stream processes are running daqd seems to write out data just fine. At least for the full frames. I manually verified that there is indeed data in the frames that are written.
Eventually, though, daqd itself crashes with the same error that we've been seeing:
main profiler warning: 0 empty blocks in the buffer
I'm not exactly sure what the crashes are coincident with, but it looks like they are also coincident with the writing out of the minute and/or second trend files. It's unclear how it's related to the mx_stream crashes, if at all. The mx_stream crashes happen every couple of minutes, whereas the daqd itself crashes much less frequently.
The new daqd can't handle EDCU files. If an EDCU file is specified (e.g. C0EDCU.ini in our case), the daqd will segfault very soon after startup. This was an issue with the current daqd on fb, but was "fixed" by moving where the EDCU file was specified in the master file.
Conclusion
There are a number of differences between the fb1 and fb configurations:
- newer OS (Debian 7 vs. ancient gentoo)
- newer advLigoRTS (trunk vs. 2.9.4)
- newer framecpp library installed from LSCSoft Debian repo (2.4.1-1+deb7u0 vs. 1.19.32-p1)
It's possible those differences could account for the problems (/opt/rtapps/epics incompatible with this Debian install, for instance). Somehow I doubt it. I wonder if all the weird network issues we've been seeing are somehow involved. If the NFS mount of chiara is problematic for some reason that would affect everything that mounts it, which includes all the front ends and fb/fb1.
There are two things to try:
- Fix the weird network problem. Try remove EVERYTHING from the network except for chiara, fb/fb1, and the front ends and see if that helps.
- Rebuild fb1 with Ubuntu and daqd as prescribed by Keith Thorne.
|