40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Sat Aug 1 17:04:29 2015, Eve, Update, Summary Pages, States and Triggers in SPs 
    Reply  Wed Sep 9 11:33:58 2015, rana, Update, Summary Pages, Summary Page updates 
Message ID: 11585     Entry time: Wed Sep 9 11:33:58 2015     In reply to: 11474
Author: rana 
Type: Update 
Category: Summary Pages 
Subject: Summary Page updates 
  • Made most plots in IOO tab only plot when MC_TRANS > 10000 using Eve's MC_LOCK state definition.
  • added the 0.03 - 0.1 Hz and 10-30 Hz bands to the PEM SEIS BLRMS tab and set the y-scales to the same as SeismicRainbowSTS.stp
  • set state PMC_LOCK in PSL tab and made some of those plots only plot when PMC trans > 0.6.
  • SUS-OL page showed me that the ETM yaw spectrum was wacky, which lead me to find that it was completely uncentered. Stop leaving the room lights ON Steve!!  angry I also set the quadrant offsets by blocking the QPD with a piece of metal (teflon doesn't work).
  • set c1summary to only plot some when X or Y arms are locked
ELOG V3.1.3-