40m QIL Cryo_Lab CTN SUS_Lab CAML OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Aug 20 02:31:09 2015, ericq, Update, LSC, PRFPMI is back lock.pdf
    Reply  Tue Aug 25 04:15:51 2015, ericq, Update, LSC, PRFPMI is back 
       Reply  Tue Aug 25 16:09:54 2015, ericq, Update, IOO, IMC Tweak imcTweak.pdfCARM_TF.pdf
          Reply  Fri Aug 28 19:05:53 2015, rana, Update, IOO, IMC Tweak 
             Reply  Tue Sep 1 11:56:56 2015, ericq, Update, IOO, IMC loop shapes IMCshapes_Aug31_2015.pdfIMC_Aug31_2015.zip
                Reply  Wed Sep 2 01:31:22 2015, ericq, Update, IOO, IMC loop shapes imc_olg_trend.pdfimc_xover_trend.pdf
       Reply  Thu Aug 27 04:23:04 2015, ericq, Update, LSC, PRFPMI is back 
          Reply  Fri Aug 28 02:20:35 2015, Ignacio, Update, LSC, PRFPMI and MCL FF carmin.pngcarmout.png
Message ID: 11558     Entry time: Wed Sep 2 01:31:22 2015     In reply to: 11555
Author: ericq 
Type: Update 
Category: IOO 
Subject: IMC loop shapes 

The promised historical comparisons follow. The crossover looks mostly the same as before. There is a new feature in the OLG at 50-60kHz; what could've changed about the EOM path in that time?

 

Attachment 1: imc_olg_trend.pdf  43 kB  | Hide | Hide all
imc_olg_trend.pdf
Attachment 2: imc_xover_trend.pdf  58 kB  | Hide | Hide all
imc_xover_trend.pdf
ELOG V3.1.3-