Message ID: 11551     Entry time: Tue Sep 1 02:44:44 2015
Author: Koji 
Type: Summary 
Category: CDS 
Subject: c1oaf, c1mcs modified for the IMC angular FF 

[Koji, Ignacio]

In order to allow us to work on the IMC angular FF, we made the signal paths from PEM to MC SUSs.
In fact, there already were the paths from c1pem to c1oaf. So, the new paths were made from c1oaf to c1mcs. (Attachment 1~3)

After some debugging those two models started running. The additional cost of the processing time is insignificant.
FB was restarted to accomodate the change.

Once the modification of the models was completed, the OAF screens were modified. It seemed that the Kissel button
for the output matrix haven't been updated for the PRM ASC implementation. This was fixed as the button was updated this time.
In addition, the button for the FM matrix was also made and pasted.

 

Attachment 1: c1oaf_screenshot1.png  134 kB  | Hide | Hide all
c1oaf_screenshot1.png
Attachment 2: c1oaf_screenshot2.png  235 kB  | Hide | Hide all
c1oaf_screenshot2.png
Attachment 3: c1mcs_screenshot.png  275 kB  | Hide | Hide all
c1mcs_screenshot.png
Attachment 4: OAF_MEDM1.png  144 kB  Uploaded Tue Sep 1 03:46:39 2015  | Hide | Hide all
OAF_MEDM1.png
Attachment 5: OAF_MEDM2.png  15 kB  Uploaded Tue Sep 1 03:46:56 2015  | Hide | Hide all
OAF_MEDM2.png
ELOG V3.1.3-