40m
QIL
Cryo_Lab
CTN
SUS_Lab
TCS_Lab
OMC_Lab
CRIME_Lab
FEA
ENG_Labs
OptContFac
Mariner
WBEEShop
|
40m Log |
Not logged in |
 |
|
|
Message ID: 11500
Entry time: Wed Aug 12 16:48:26 2015
In reply to: 11499
|
Author: |
Ignacio |
Type: |
Update |
Category: |
IOO |
Subject: |
Better? Nope. MISO WIener (T240-X and T240-Y) FF of MCL |
|
|
Last night, I also worked on a "better" (an improvement, I thought) of the MISO Wiener filter (T240-X and T240-Y witnesses) IIR filter. The FF results are shown below:
Filter:
T240-X

T240-Y
Training data + Predicted FIR and IIR subtraction:
Online subtraction results:
MCL
YARM
Although the predicted FIR and IIR results are "better" than the previous MISO filter, the subtraction performance for this filter is marginally better if not worse (both peak at 15 dB, in slightly different regions). |
|
|
|
|
|
|
|
|
|
|
|
|