Message ID: 11480     Entry time: Wed Aug 5 17:15:08 2015
Author: Eve 
Type: Update 
Category: Summary Pages 
Subject: Fixed ASC Tab 

I've fixed the ASC tab on the summary pages to populate the graphs with data without causing an error.

Motivation: The ASC tab was showing no data. It resulted in a name error when generated.

What I did:

A name error indicates a bad channel name in the plot definition. I identified two errors in the code:

  1. I said C1:SUS_MC1_ASCPIT_OUT16.mean instead of C1:SUS-MC1_ASCPIT_OUT16.mean (underscore should be dash)
  2. The channel C1:ASX-XARM_M1_PUT_OSC_CLKGAIN was resulting in a name error. I removed it.

Results:

The plots are not processing without error. However, no titles or axis labels are present on the plots- I'll work on adding these.

 