40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 11445     Entry time: Fri Jul 24 20:32:15 2015
Author: ericq 
Type: Update 
Category: Electronics 
Subject: LSC LO distribution box power button replaced  

As happened with the RF distribution box in the IOO rack a while back, the shiny blue power button in the LSC LO distribution box failed today. I replaced it with a simple switch, but since the original was a double throw, the replacement was way too big to fit without major panel surgery. So, instead, I installed it in the grille on the roof of the chassis. It a tight press/snap fit, though; I don't think it is at risk of easily coming loose. 

After reinstalling the box, I confirmed that POX POY and AS55 could all lock arms, so I deem the operation a success.

Before:

After:

Attachment 1: 2015-07-24_15.43.56.jpg  148 kB  Uploaded Fri Jul 24 23:23:16 2015  | Hide | Hide all
2015-07-24_15.43.56.jpg
Attachment 2: 2015-07-24_16.57.19.jpg  178 kB  Uploaded Fri Jul 24 23:23:26 2015  | Hide | Hide all
2015-07-24_16.57.19.jpg
ELOG V3.1.3-