40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 1141     Entry time: Mon Nov 17 16:59:22 2008
Author: Jenne 
Type: Update 
Category: PEM 
Subject: Seismometer hooked up, reading channels on DataViewer 
Alberto, Jenne

The Guralp Seismometer is (finally) hooked up to the PEM ADCU. Alberto helped me make channels in the c1pem1 .ini file, which correspond to:

Guralp1 VERT = channel 9 on PEM ADCU = C1:PEM-SEIS_MC1_VERT
Guralp1 NS = channel 10 on PEM ADCU = C1:PEM-SEIS_MC1_NS
Guralp1 EW = channel 11 on PEM ADCU = C1:PEM-SEIS_MC1_EW

We also renamed the Ranger seismometer's channel to C1:PEM-SEIS_MC2_Y from C1:PEM-SEIS_MC1_Y, since tomorrow I'll move the Ranger Seismometer to be underneath MC2's chamber (it's currently sitting somewhere in the middle of the Mode Cleaner).


I can see the VERT and NS channels with dataviewer, but EW looks dead. I need to figure out if this is a bad cable thing, or if the ADC channel is no good, or if something in the box on that channel is no good. All 3 channels were tested and working after all the soldering was completed by Caryn, but something may have come undone while putting the box into its new place in the top of 1Y1. (In dataviewer, it looks like the EW channel is just floating, and not connected to anything.)

Plan of Attack:
* figure out why EW looks dead on Dataviewer
* redo Rana's static Wiener filter analysis, now that we have 2 seismometers (1 Ranger and 1 Guralp)
* work on adaptive Wiener filtering with the Guralp
ELOG V3.1.3-