40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Tue Jun 30 11:33:00 2015, Jamie, Summary, CDS, prepping for CDS upgrade 
    Reply  Wed Jul 1 19:16:21 2015, Jamie, Summary, CDS, CDS upgrade in progress 
       Reply  Tue Jul 7 18:27:54 2015, Jamie, Summary, CDS, CDS upgrade: progress! 2.9-RTS-OK.pngC1X04_GDS_TP.png
          Reply  Wed Jul 8 20:37:02 2015, Jamie, Summary, CDS, CDS upgrade: one step forward, two steps back 
             Reply  Wed Jul 8 21:02:02 2015, Jamie, Summary, CDS, CDS upgrade: another step forward, so we're back to where we started (plus a bit?) 
                Reply  Thu Jul 9 13:26:47 2015, Jamie, Summary, CDS, CDS upgrade: new mx 1.2.16 installed 
                   Reply  Thu Jul 9 16:50:13 2015, Jamie, Summary, CDS, CDS upgrade: if all else fails try throwing metal at the problem 
                      Reply  Mon Jul 13 01:11:14 2015, Jamie, Summary, CDS, CDS upgrade: current assessment 
                         Reply  Mon Jul 13 18:12:50 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 09:08:37 2015, Jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                               Reply  Tue Jul 14 10:28:02 2015, ericq, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                                  Reply  Tue Jul 14 11:57:27 2015, jamie, Summary, CDS, CDS upgrade: left running in semi-stable configuration 
                            Reply  Tue Jul 14 16:51:01 2015, Jamie, Summary, CDS, CDS upgrade: problem is not disk access 
                               Reply  Wed Jul 15 13:19:14 2015, Jamie, Summary, CDS, CDS upgrade: reducing mx end-points as last ditch effort 
                                  Reply  Wed Jul 15 18:19:12 2015, Jamie, Summary, CDS, CDS upgrade: tentative stabilty? 
                                     Reply  Sat Jul 18 15:37:19 2015, Jamie, Summary, CDS, CDS upgrade: current status cds-good.pngsus-damped.png
Message ID: 11398     Entry time: Thu Jul 9 13:26:47 2015     In reply to: 11397     Reply to this: 11400
Author: Jamie 
Type: Summary 
Category: CDS 
Subject: CDS upgrade: new mx 1.2.16 installed 

I rebuilt/installed mx 1.2.16 to use "ether-mode", instead of the default MX-10G:

controls@fb /opt/src/mx-1.2.16 0$ ./configure --enable-ether-mode --prefix=/opt/mx-1.2.16
...
controls@fb /opt/src/mx-1.2.16 0$ make
..
controls@fb /opt/src/mx-1.2.16 0$ make install
...

I then rebuilt/installed daqd so that it properly linked against the updated mx install:

controls@fb /opt/rtcds/rtscore/release/src/daqd 0$ ./configure --enable-debug --disable-broadcast --without-myrinet --with-mx --with epics=/opt/rtapps/epics/base --with-framecpp=/opt/rtapps/framecpp --enable-local-timing
...
controls@fb /opt/rtcds/rtscore/release/src/daqd 0$ make
...
controls@fb /opt/rtcds/rtscore/release/src/daqd 0$ install daqd /opt/rtcds/caltech/c1/target/fb/

It's now back to running and receiving data from the front ends (still not stable yet, though).

ELOG V3.1.3-