40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 11392     Entry time: Tue Jul 7 17:22:16 2015
Author: Jessica 
Type: Summary 
Category:  
Subject: Time Delay in ALS Cables 

I measured the transfer functions in the delay line cables, and then calculated the time delay from that.

The first cable had a time delay of 1272 ns and the second had a time delay of 1264 ns. 

Below are the plots I created to calculate this. There does seem to be a pattern in the residual plots however, which was not expected. 

The R-Square parameter was very close to 1 for both fits, indicating that the fit was good. 

Attachment 1: cableA_fit.jpg  66 kB  | Show | Show all
Attachment 2: cableA_resid.jpg  44 kB  | Show | Show all
Attachment 3: cableB_fit.jpg  67 kB  | Show | Show all
Attachment 4: cableB_resid.jpg  46 kB  | Show | Show all
ELOG V3.1.3-