Entry  Tue May 5 10:40:05 2015, ericq, HowTo, Computer Scripts / Programs, How to get a web page running on Nodus 
    Reply  Sun May 10 13:54:41 2015, rana, HowTo, Computer Scripts / Programs, summary page URL change 
       Reply  Mon May 11 01:28:33 2015, rana, HowTo, Computer Scripts / Programs, summary page URL change 
          Reply  Mon May 11 13:26:02 2015, manasa, Update, IMC, MC_F calibration 
             Reply  Mon May 11 18:14:52 2015, rana, Update, IMC, MC_F calibration 
Message ID: 11278     Entry time: Mon May 11 01:28:33 2015     In reply to: 11277     Reply to this: 11281
Author: rana 
Type: HowTo 
Category: Computer Scripts / Programs 
Subject: summary page URL change 

Like Steve pointed out, the summary pages show that the y-arm transmission drifts a lot when locked. The OL summary page shows that this is all due to ITMY yaw.

Could be either that they coil driver / DAC is bad or that the suspension is poorly built. We need to dig into ITMY OL trends over long term to see if this is new or now.

Also, weather station needs a reboot. And does anyone know what the MC_F calibration is?