Entry  Fri Apr 24 01:16:30 2015, Jenne, Update, ASC, Broken Xass? 
    Reply  Sat Apr 25 03:32:45 2015, Koji, Update, ASC, Broken Xass? 
       Reply  Sun Apr 26 01:10:18 2015, rana, Update, ASC, unBroken Xass? xasstune_150426.pngxassnoise.pdf
          Reply  Sun Apr 26 15:05:35 2015, Jenne, Update, ASC, unBroken Xass? 
Message ID: 11242     Entry time: Fri Apr 24 01:16:30 2015     Reply to this: 11248
Author: Jenne 
Type: Update 
Category: ASC 
Subject: Broken Xass? 

I ran the "off" script for the Xarm ASS, followed by the "on" script, and now the Xarm ASS doesn't work.  Usually we just run the freeze/unfreeze, but I ran the off/on scripts one time. 

Koji, if you have some time tomorrow, can you please look at it?  I am sorry to ask, but it would be very helpful if I could keep working on other things while the ASS is taken care of.

Steve, can you please find a cable that goes from the LSC rack to the IOO rack (1Y2 to 1X2), or lay a new one?  It must be one single long cable, without barrels sticking it together.  This will help me actuate on the Marconi using the LSC rack's DAC. 

Thank you!!