40m Log |
Not logged in |
 |
|
Sun Nov 2 20:44:58 2008, rana, Update, ASS, Wiener Filter performance over 5 hours 
|
Mon Nov 3 22:35:40 2008, rana, Update, ASS, Wiener Filter performance over 5 hours
|
Tue Nov 4 00:47:53 2008, rana, Update, ASS, Wiener Filter performance over 5 hours 
|
|
Message ID: 1111
Entry time: Mon Nov 3 22:35:40 2008
In reply to: 1105
|
Author: |
rana |
Type: |
Update |
Category: |
ASS |
Subject: |
Wiener Filter performance over 5 hours |
|
|
To speed up the Wiener filter work I defined a 256 Hz version of the original 16kHz IOO-MC_L signal. The
attached plots show that the FE decimation code works correctly in handling the anti-aliasing and
downsampling as expected. |
|
|