40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 11094     Entry time: Tue Mar 3 19:19:15 2015
Author: ericq 
Type: Update 
Category: IOO 
Subject: PC Drive / FSS Slow correlation 

Jenne and I were musing the other night that the PC drive RMS may have a "favorite" laser temperature, as controlled by the FSS Slow servo; maybe around 0.2.

I downloaded the past 30 days of mean minute trend data for MC Trans, FSS Slow and PC Drive, and took the subset of data points where transmission was more than 15k, and the FSS slow output was within 1 count of zero. (This was to exclude some outliers when it ran away to 3 for some days). This was about 76% of the data. I then made some 2D histograms, to try and suss out any correlations. 

Indeed, the FSS slow servo does like to hang out around 0.2, but this does not seem to correlate with better MC transmission nor lower PC drive.

In the following grid of plots, the diagonal plots are the 1D histograms of each variable in the selected time period. The off diagnoal elements are the 2D histograms. They're all pretty blob-y, with no clear correlation. 

Attachment 1: jointplot.png  141 kB  | Hide | Hide all
jointplot.png