Message ID: 11092     Entry time: Tue Mar 3 09:42:40 2015     In reply to: 11088
Author: Steve 
Type: Update 
Category: SUS 
Subject: ETMX is drifting 

The temperature of the east and south ends  are normal, they are about the same.

 

Attachment 1: ETMXdrifting.png  68 kB  | Hide | Hide all
ETMXdrifting.png
Attachment 2: ETMXvsTemp.png  53 kB  | Hide | Hide all
ETMXvsTemp.png