Better elog tomorrow - notes for now:

REFL165 for PRMI has been "a champ" (quote from Q).  We're able to sit on ALS at average arm powers of 30ish.  Nice. 

Some ALSfool work - measured cancellation almost as good as single arm. 

One time transitioned CARM -> normalized REFL55I

Many times did DARM -> normalized AS55Q, see lots of noise at 39ish Hz - may be coupling from MICH??

Arm ASC loops helped improve dark port contrast. 

Note to selfs:  Need to make sure DTT templates have correct freq ordering - must be small freqs to large freqs.