Author: jamie 
Type: Update 
Category: Computer Scripts / Programs 
Subject: FB IO load 
We should use "ionice" to throttle the rsync. Use something like "ionice -c 3 rsync ..." to set the priority such that the rsync process will only work when there is no other IO contention. See "man ionice" for other options.