Fri Feb 20 19:09:48 2015, ericq, Update, ASC, QPD frontend code unified
|
Mon Feb 23 08:06:59 2015, rana, Update, ASC, QPD frontend code unified
|
Thu Mar 5 20:44:30 2015, Jenne, Update, SUS, damprestore script updated
|
Mon Mar 9 18:10:59 2015, Jenne, Update, ASC, Oplev filters re-copied
|
Sat Mar 14 00:12:18 2015, rana, Update, SUS, Oplevs huh?
|
Mon Mar 23 13:27:33 2015, ericq, Update, SUS, ITMX oplev quadrant gains unbalanced
|
Fri Apr 3 14:57:38 2015, manasa, Update, SUS, BS oplev
|
Fri Apr 3 15:15:55 2015, Steve, Update, SUS, BS oplev
|
Fri Apr 3 19:35:14 2015, Jenne, Update, SUS, BS oplev centered
|
|
Message ID: 11057
Entry time: Mon Feb 23 08:06:59 2015
In reply to: 11056
|
Author: |
rana |
Type: |
Update |
Category: |
ASC |
Subject: |
QPD frontend code unified |
|
|
Might have to also get the OL screens that go with this new code to see, but the calibrations don't go into the matrix, but rather into the OLPIT/OLYAW filter banks which follow the division, but before the servo filter banks. |