Wed Feb 11 18:11:46 2015, Koji, Summary, LSC, 3f modulation cancellation
|
Thu Feb 12 23:47:45 2015, Koji, Update, LSC, 3f modulation cancellation
|
Sat Feb 14 00:48:13 2015, Koji, Update, LSC, 3f modulation cancellation
|
Sat Feb 14 19:54:04 2015, Koji, Summary, LSC, 3f modulation cancellation  
|
Sat Feb 14 20:37:51 2015, Koji, Summary, LSC, 3f modulation cancellation   
|
Sat Feb 14 22:14:02 2015, Koji, Summary, LSC, [HOW TO] 3f modulation cancellation  
|
Sun Feb 15 16:20:44 2015, Koji, Summary, LSC, [ELOG LIST] 3f modulation cancellation
|
Sun Feb 15 20:55:48 2015, rana, Summary, LSC, [ELOG LIST] 3f modulation cancellation
|
Mon Feb 16 00:08:44 2015, Koji, Summary, LSC, [ELOG LIST] 3f modulation cancellation
|
Mon Feb 16 01:45:12 2015, Koji, Summary, LSC, modulation depth analysis 
|
|
Message ID: 11034
Entry time: Sun Feb 15 20:55:48 2015
In reply to: 11033
Reply to this: 11035
|
Author: |
rana |
Type: |
Summary |
Category: |
LSC |
Subject: |
[ELOG LIST] 3f modulation cancellation |
|
|
I wonder if DRMI can be locked on 3f using this lower 55 MHz modulation depth. It seems that PRMI should be unaffected, but that the 3*f2 signals for SRCL will be too puny. Is it really possible to scale up the overall modulation depths by 3x to compensate for this? |