Message ID: 11034     Entry time: Sun Feb 15 20:55:48 2015     In reply to: 11033     Reply to this: 11035
Author: rana 
Type: Summary 
Category: LSC 
Subject: [ELOG LIST] 3f modulation cancellation 

I wonder if DRMI can be locked on 3f using this lower 55 MHz modulation depth. It seems that PRMI should be unaffected, but that the 3*f2 signals for SRCL will be too puny. Is it really possible to scale up the overall modulation depths by 3x to compensate for this?