Message ID: 11000     Entry time: Wed Feb 11 03:41:12 2015     In reply to: 10999     Reply to this: 11003
Author: Koji 
Type: Update 
Category: LSC 
Subject: PRC error signal RF spectra 

As the measurements have been done under feedback control, the lower RF peak height does not necessary mean
the lower optical gain although it may be the case this time.

These non-33MHz signals are embarassingly high!
We also need to check how these non-primary RF signals may cause spourious contributions in the error signals,
including the other PDs.