40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Jan 7 14:35:44 2015, diego, Update, SUS, SUS Drift Monitor 150107_SUS_DRIFTMON_screen.png
    Reply  Thu Jan 8 23:02:30 2015, diego, Update, SUS, SUS Drift Monitor 150108_SUS_DRIFTMON_screen.png
       Reply  Tue Jan 20 19:32:06 2015, Jenne, Update, SUS, SUS Drift restore scripts 
          Reply  Fri Jan 23 10:07:15 2015, Steve, Update, SUS, SUS Drift ETMX vs ETMY SUSdrift30d.png
             Reply  Mon Mar 2 18:34:12 2015, Jenne, Update, SUS, ETMX moving during single arm lock ETMX_moving.pngETMXmoving_ALSlock.pngStartsMoving_stopsItself_ranASS.png80mHz.pngIndependFromFSStemp.png
                Reply  Tue Mar 3 09:42:40 2015, Steve, Update, SUS, ETMX is drifting ETMXdrifting.pngETMXvsTemp.png
             Reply  Fri Sep 25 14:52:08 2015, Steve, Update, SUS, ETMX is not drifting ETMXstoppedDrifting.png25daysArmsT.png
                Reply  Fri Sep 25 19:06:13 2015, rana, Update, SUS, ETMX IS drifting 
Message ID: 10934     Entry time: Fri Jan 23 10:07:15 2015     In reply to: 10924     Reply to this: 11088   11643
Author: Steve 
Type: Update 
Category: SUS 
Subject: SUS Drift ETMX vs ETMY 

ETMX YAW stopped drifting Jan 8, 2015

Quote:

I made little scripts to go with the sus driftmon buttons, that will servo the alignment sliders until the susyaw and suspit values match the references on the driftmon screen.

Attachment 1: SUSdrift30d.png  82 kB  | Hide | Hide all
SUSdrift30d.png
ELOG V3.1.3-