Entry time: Tue Jan 13 23:17:57 2015
|
Author: |
Chris |
Type: |
Frogs |
Category: |
Computer Scripts / Programs |
Subject: |
medm time machine |
|
|
After recompiling medm with a patch for dumping screens (attached), I added a time machine to the right-click Execute menu. It's installed under /cvs/cds/caltech/users/wipf/src/medm_time_machine. Dependencies include the python CA server module (pcaspy) and the latest nds2-client 0.11.2. These were also installed under my users directory, to avoid interfering with other tools.
|
|
|
|
--- /ligo/apps/epics-3.14.12_long/extensions/src/medm/medm/utils.c.orig 2015-01-13 18:56:44.867720104 -0800
+++ /ligo/apps/epics-3.14.12_long/extensions/src/medm/medm/utils.c 2015-01-13 22:49:56.636820963 -0800
@@ -4156,6 +4156,37 @@
timeOffset = time900101 - time700101;
}
+#if((2*MAX_TRACES)+2) > MAX_PENS
+#define MAX_COUNT 2*MAX_TRACES+2
+#else
+#define MAX_COUNT MAX_PENS