Entry time: Mon Jan 5 12:42:09 2015
In reply to: 10850
|
Author: |
ericq |
Type: |
Update |
Category: |
SUS |
Subject: |
BS misbehaving |
|
|
The BS was showing some excess motion. I think I've fixed it. Order of operations:
- The DC PIT bias from previous ASS runs was at ~500, I zeroed this and aligned the BS to be centered on its oplev QPD with DC alignment sliders
- I squished the gold box cables. This changed the alignment slightly, and brought the UR voltage back to a normal value. Excess motion still existed
- I found that the the
C1:SUS-BS_LRSEN filter had HOLD OUTPUT enabled. I turned it off. All seems well.
I'm not sure how this might have gotten switched on... |