40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Fri Dec 19 18:08:46 2014, Jenne, Update, CDS, SOS!!! HELP!! EPICS freeze 45min+ so far! 
    Reply  Fri Dec 19 19:21:04 2014, diego, Update, CDS, SOS!!! HELP!! EPICS freeze 45min+ so far! 
       Reply  Fri Dec 19 20:32:11 2014, diego, Update, CDS, SOS!!! HELP!! EPICS freeze 45min+ so far! 
Message ID: 10823     Entry time: Fri Dec 19 20:32:11 2014     In reply to: 10822
Author: diego 
Type: Update 
Category: CDS 
Subject: SOS!!! HELP!! EPICS freeze 45min+ so far! 

[Diego, Jenne]

 

Everything seems reasonably back to normal:

Notes:

  • the machines in the control room have been rebooted;
  • the c1iscey frontend now behaves;
  • I saw on nodus, which remained up and running the whole time, a bunch of   nfs: server chiara is not responding, timed out  messages, belonging to the freezing time; it may be that the sync option for the nfs share is too resource demanding, or some other network issue;
  • the FSS was doing strange stuff and the MC couldn't recover the lock; the MCautolocker script wasn't running because of the lock loss of the MC and the lack of communication between the machines; so we did a sudo initctl start MCautolocker on megatron and recovered the MC too.