Entry  Thu Dec 18 16:21:08 2014, ericq, Update, Computer Scripts / Programs, scripts not being backed up! 
    Reply  Fri Dec 19 16:59:32 2014, ericq, Update, Computer Scripts / Programs, FSS Slow servo moved to megatron 
       Reply  Fri Dec 19 20:44:23 2014, Jenne, Update, Computer Scripts / Programs, FSS Slow servo moved to megatron 
          Reply  Sat Dec 20 00:00:03 2014, ericq, Update, Computer Scripts / Programs, FSS Slow servo moved to megatron 
             Reply  Tue Dec 23 18:43:33 2014, diego, Update, Computer Scripts / Programs, FSS Slow servo moved to megatron 
                Reply  Fri Dec 26 18:20:42 2014, rana, Update, Computer Scripts / Programs, FSS Slow servo thresh change 
Message ID: 10820     Entry time: Fri Dec 19 16:59:32 2014     In reply to: 10816     Reply to this: 10824
Author: ericq 
Type: Update 
Category: Computer Scripts / Programs 
Subject: FSS Slow servo moved to megatron 

Given that op340m showed some undesired behavior, and that the FSS slow seems prone to railing lately, I've moved the FSS slow servo job over to megatron in the same way I did for the MC autolocker. 

Namely, there is an upstart configuration (megatron:/etc/init/FSSslow.conf), that invokes the slow servo. Log file is in the same old place (/cvs/cds/caltech/logs/scripts), and the servo can be (re)started by running: 

controls@megatron|~ > sudo initctl start FSSslow

Maybe this won't really change the behavior. We'll see