40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Wed Dec 10 15:05:32 2014, Jenne, Update, Electronics, Xend QPD whitening board modified already IMG_1776.JPG
    Reply  Thu Dec 11 16:42:12 2014, Jenne, Update, Electronics, Xend QPD whitening board plan QPDwhiteningModification_11Dec2014.pdf
       Reply  Fri Dec 12 19:54:21 2014, Jenne, Update, Electronics, Xend QPD whitening board modified QPDwhiteningModification_XtransCompleted_12Dec2014.pdfIMG_1779.JPGQPD_Xtrans_Ytrans_12Dec2014.pdfQPD_Xtrans_Ytrans_DarkVsLock_12Dec2014.pdf
          Reply  Sat Dec 13 00:35:11 2014, rana, Update, Electronics, Xend QPD whitening board modified 
          Reply  Mon Dec 15 22:30:50 2014, Jenne, Update, Electronics, Yend QPD modified 
             Reply  Mon Dec 15 22:45:59 2014, Jenne, Update, Electronics, Yend QPD modified QPD_Ytrans_oscillating_15Dec2014.pdfQPD_IOPchannels_Ytrans_oscillating_15Dec2014.pdf
                Reply  Fri Feb 13 14:27:30 2015, ericq, Update, Electronics, Second QPD Whitening Switch enabled 
                   Reply  Fri Feb 13 14:59:13 2015, ericq, Update, Electronics, Second QPD Whitening Switch enabled 
                      Reply  Fri Feb 13 18:56:44 2015, rana, Update, Electronics, Second QPD Whitening Switch enabled 
                         Reply  Thu Feb 19 04:09:21 2015, ericq, Update, Electronics, Second QPD Whitening Switch enabled 
                   Reply  Fri Feb 13 17:07:51 2015, Jenne, Update, Electronics, Second QPD Whitening Switch enabled 
Message ID: 10799     Entry time: Mon Dec 15 22:30:50 2014     In reply to: 10794     Reply to this: 10801
Author: Jenne 
Type: Update 
Category: Electronics 
Subject: Yend QPD modified 

Details later - empty entry for a reply.

Short story - Yend is now same as Xend filters-wise and lack of gain sliders -wise.  Both ends have 13.7k resistors around the AD620 to give them gains of ~4.5.

Xend seems fine.

Yend seems not fine.  Even the dark noise spectrum sees giganto peaks.  See Diego's elog 10801 for details on this investigation.