Message ID: 10793     Entry time: Fri Dec 12 19:38:49 2014     In reply to: 10772     Reply to this: 10797
Author: diego 
Type: Update 
Category: Computer Scripts / Programs 
Subject: Status of the new nodus 

Quote:

[Diego, Steve]

We ran a Cat 6+ Ethernet cable from the 1X7 rack (where the new nodus is located) to the fast GC switch in the control room rack; now I will learn how to setup the 'outside world' network, iptables, and the like.

 

I remind that the current hardware/software status is posted in elog 10697 ; if additions or corrections are needed, let me know.

 

After I check a couple of things, we can use the new nodus (which is currently known in the martian network as rosalba) as a local test to see that everything is working. After that (and, mostly, after I'll have the network working), we will sync the data from the old nodus to the new one and make the switch.

[Diego, EricQ]

Update: work is almost completed; the old nodus is still online, as I don't feel confident to make the switch and leave it on its own for the weekend. However, the new nodus is online with the IP address 131.215.114.87, so everyone can check that everything works. From my tests I can say that:

After everything will be in place, I will save every reasonably important configuration file of nodus into the svn.

 

I remind that every change made while accessing the 131.215.114.87 machine will be purged during the sync&switch

 