40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Thu Nov 13 01:03:28 2014, rana, jenne, Update, SUS, OL updates on ITMs and ETMs 
    Reply  Fri Nov 14 19:28:33 2014, Jenne, Update, SUS, ASS gain reduced for Yarm 
Message ID: 10719     Entry time: Fri Nov 14 19:28:33 2014     In reply to: 10708
Author: Jenne 
Type: Update 
Category: SUS 
Subject: ASS gain reduced for Yarm 

[Koji, Jenne]

We noticed last night that the yarm couldn't handle the old nominal gain for the ASS servos.  We were able to run the ASS using about 0.3 in the overall gain.  So, I have reduced the gain in each of the individual servos by a factor of 3, so that the scripts work, and can set the overall gain to 1.