[Rana, Jenne]
We're summarizing the discussions of the last few days as to the game plan for locking.
- PRMI on REFL165. The factor of 5 in frequency will give us more MICH signal. We want this.
- Drive CARM, measure coupling to PRCL, MICH while locked on REFL33.
- Switch to REFL165, re-measure CARM coupling.
- Hopefully this will reduce the AS port fluctuations, and reduce the POP22 power decrease as CARM offset decreases.
- DARM transition from ALSdiff to an intermediate signal. Simulate, and try empirically.
- Maybe try ASDC normalized by sum of transmissions?
- Maybe try difference of transmissions divided by sum of transmissions?
- Look at data on disk.
- Do we have anything specific causing our locklosses (lately there haven't been obvious loop instabilities causing the locklosses)?
- How much do we think our lengths are actually changing right now (particularly DARM on ALSdiff)?
- Are there better ways of combining error signals that could be useful?
- Do we need to work on angular loops?
- Oplevs
- POP ASC for sidebands
- POP QPD or Trans QPDs for arms
- Think about what could be causing ETMX to be annoying. The connection that is most suspect has been ziptied, but we're still seeing ETMX move either at locklosses or sometimes just spontaneously.
- RAM. What kind of RAM levels do we have right now, and how do they affect our locking offsets? Do we have big offsets, or negligible offsets?
|