40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Message ID: 10406     Entry time: Mon Aug 18 09:42:50 2014
Author: Koji 
Type: Summary 
Category: IOO 
Subject: MCREFL PD charcterization 

Riju did the measurement of the MCREFL PD.
I found data files in her directory on the control machine.

I was not sure how much was the transimpedance of the DC out.
I assumed the default number from the circuit diagram which was 66.7Ohm.
This may cause the error in absolute caribration of the transimpedance but the shape does not change.

The RF preamp is gain-peeking at 250MHz.

Here is further characterization of the PD response.
As you can see in the second attachment, the 3dB cut off of the resonance is about 2.3MHz.

The game plan file in dropbox was also modified.

Attachment 1: MCREFLPD_transimpedance.pdf  157 kB  | Hide | Hide all
MCREFLPD_transimpedance.pdf
Attachment 2: MCREFLPD_transimpedance_zoom.pdf  25 kB  | Hide | Hide all
MCREFLPD_transimpedance_zoom.pdf
ELOG V3.1.3-