40m QIL Cryo_Lab CTN SUS_Lab TCS_Lab OMC_Lab CRIME_Lab FEA ENG_Labs OptContFac Mariner WBEEShop
  40m Log  Not logged in ELOG logo
Entry  Mon Jun 16 21:56:53 2014, Jenne, Update, Computer Scripts / Programs, fstab updates, MC autolocker running, FSS slow loop alive 
    Reply  Tue Jun 17 12:04:40 2014, manasa, Update, Computer Scripts / Programs, MC autolocker NOT running, FB needs some attention FE_red.png
       Reply  Tue Jun 17 16:52:40 2014, ericq, Update, Computer Scripts / Programs, autolocker confusion 
          Reply  Tue Jun 17 19:39:29 2014, rana, Update, Computer Scripts / Programs, autolocker confusion 
             Reply  Wed Jun 18 11:28:19 2014, Manasa, Update, Computer Scripts / Programs, autolocker confusion 
                Reply  Wed Jun 18 13:29:48 2014, rana, Update, Computer Scripts / Programs, autolocker confusion 
                   Reply  Wed Jun 18 17:38:14 2014, Jenne, Update, Computer Scripts / Programs, autolocker running again 
                      Reply  Thu Jun 19 16:49:15 2014, rana, Update, Computer Scripts / Programs, autolocker running again 
                         Reply  Thu Jun 19 22:04:23 2014, ericq, Update, Computer Scripts / Programs, caget/caput now return in reasonable time 
                            Reply  Fri Jun 20 09:46:49 2014, manasa, Update, IOO, MC WFS servo turned ON 
                            Reply  Fri Jun 20 19:07:44 2014, rana, Update, Computer Scripts / Programs, op340m DNS 
                               Reply  Tue Jun 24 22:46:15 2014, ericq, Update, Computer Scripts / Programs, op340m crons 
       Reply  Tue Jun 17 17:04:26 2014, ericq, Update, Computer Scripts / Programs, FB troubles 
Message ID: 10046     Entry time: Mon Jun 16 21:56:53 2014     Reply to this: 10048
Author: Jenne 
Type: Update 
Category: Computer Scripts / Programs 
Subject: fstab updates, MC autolocker running, FSS slow loop alive 

[Rana, Jenne]

Mc autolocker:

MC autolocker is running.  The trouble was with caput and caget and cavput on Pianosa.  Rana has switched those lines in mcup and mcdown over to ezcaread and ezcawrites, and that seems to have fixed things. For the MC2tickleON and -OFF scripts, we left the caput and caget and cavput, and saw that they do run successfully on Ottavia.  (We tried testing again on Pianosa, and now it seems to be okay with cavput, but we promise it was hanging up on this earlier this evening.)  Anyhow, it's all a bit confusing, but it seems to be running fine now.

The autolocker is now running on Ottavia, and Rana is putting it into Ottavia's cronjob list, and commented it out on op340m.

 

fstab changes:

We have removed the option "all_squash" from /etc/exports on Chiara (both lines).  We then checked that the files have ownership "controls controls" on Chiara, Pianosa and Rossa.  Ottavia still has ownership of "nobody nogroup", so we still need to figure that out. 

 

FSS slow loop:

We confirmed that the slow loop is running.  Also, since caput and caget seem to take a while, and the real PID integral gain is the value that we set times a sampling rate, the effective gain had changed.  So, Rana compensated by changing C1:PSL-FSS_SLOWKI from 0.03 to 0.1. 

 

Other thoughts:

Do we have an autoburt saver on another computer, in addition to op340m?  (It's in the op340m crontab list)  We really only want one of these at a time.

 