Entry  Mon Jun 9 11:42:00 2014, Jenne, Update, CDS, Computer status 
    Reply  Mon Jun 9 12:19:17 2014, ericq, Update, CDS, Computer status 
       Reply  Mon Jun 9 22:26:44 2014, rana, zach, Update, CDS, SLOW controls recovery 
          Reply  Wed Jun 11 14:36:57 2014, Jenne, Update, CDS, SLOW controls recovery 
             Reply  Wed Jun 11 15:57:18 2014, Jenne, Update, CDS, Note on cables for talking to slow computers 06111401.PDF
                Reply  Thu Jun 12 15:31:47 2014, Jamie, Update, CDS, Note on cables for talking to slow computers 
             Reply  Wed Jun 11 16:01:31 2014, Steve, Update, CDS, c1Vac1 and c1vac2 rebooted beforeReboot.png
                Reply  Fri Oct 10 14:27:44 2014, Steve, Update, CDS, c1Vac1 and c1vac2 reboot was a failure c1vac1resetReboot.pngc1Vac1&2down.jpg
       Reply  Wed Oct 8 15:31:31 2014, Jenne, Update, CDS, Computer status 
    Reply  Mon Jun 9 22:40:36 2014, Jenne, Update, CDS, Fast front end computers up 
    Reply  Tue Jun 10 09:25:29 2014, Jamie, Update, CDS, Computer status: should not be changing names 
Message ID: 10011     Entry time: Mon Jun 9 12:19:17 2014     In reply to: 10010     Reply to this: 10015   10585
Author: ericq 
Type: Update 
Category: CDS 
Subject: Computer status 

Quote:

The first nameserver on all of the workstation machines inside of the file /etc/resolv.conf has been changed to be 192.168.113.104, which is Chiara's IP address (it used to be 192.168.113.20, which was linux1).  This change has also been made on the framebuilder, and in the framebuilder's /diskless/root/etc/resolv.conf file, which is what all of the fast front ends look to. 

On the framebuilder, and in the /diskless place for the fast front ends, presumably we must have changed something to point at the new location for the shared drive, but I don't remember how we did that [ERIC, what did we do???]

In all of the fstabs, we're using chiara's IP instead of name, so that if the nameserver part isn't working, we can still get the NFS mounts.

On control room computers, we mount the NFS through /etc/fstab having lines like:

192.168.113.104:/home/cds /cvs/cds nfs rw,bg 0 0
fb:/frames /frames nfs ro,bg 0 0

Then, things like /cvs/cds/foo are locally symlinked to /opt/foo

For the diskless machines, we edited the files in /diskless/root. On FB, /diskless/root/etc/fstab becomes

master:/diskless/root                   /         nfs     sync,hard,intr,rw,nolock,rsize=8192,wsize=8192    0 0
master:/usr                             /usr      nfs     sync,hard,intr,ro,nolock,rsize=8192,wsize=8192    0 0
master:/home                            /home     nfs     sync,hard,intr,rw,nolock,rsize=8192,wsize=8192    0 0
none                                    /proc     proc    defaults          0 0
none                                    /var/log        tmpfs   size=100m,rw    0 0
none                                    /var/lib/init.d tmpfs   size=100m,rw    0 0
none                                    /dev/pts        devpts  rw,nosuid,noexec,relatime,gid=5,mode=620        0 0
none                                    /sys            sysfs   defaults        0 0
master:/opt                             /opt      nfs    async,hard,intr,rw,nolock  0 0
192.168.113.104:/home/cds/rtcds         /opt/rtcds      nfs     nolock  0 0
192.168.113.104:/home/cds/rtapps        /opt/rtapps     nfs     nolock  0 0

("master" is defined in /diskless/root/etc/hosts to be 192.168.113.202, which is fb's IP)

and /diskless/root/etc/resolv.conf becomes:

search martian

nameserver 192.168.113.104 #Chiara

 

 